The applicant shall develop and submit, with the permit application, a site preparation plan that illustrates how site preparation will alleviate potential site-specific limitations and ensure suitability for the subsurface area drip dispersal system. This plan must include the following if applicable:
(1) a site plan to minimize rainfall run-on and maximize rainfall runoff from the dispersal zones;
(2) design criteria to compensate for any restrictive horizons within the soil column;
(3) soil importation with descriptions of the chemical and physical characteristics of the proposed import material; and
(4) any planned removal of existing vegetation.
Source Note: The provisions of this §222.75 adopted to be effective July 5, 2006, 31 TexReg 5308; amended to be effective January 9, 2020, 45 TexReg 363